Testo 435-2 - Multi-function Instrument for VAC & IAQ
With readings memory, PC software and USB data transfer cable, includes battery and calibration protocol
The measuring instrument for ambient air conditions, for assessment of Indoor Air Quality and adjusting and testing VAC systems, stands out on account of its efficient measurement process. Probe-controlled menus and selectable user profiles, e.g. for duct measurement or long-term measurement, ensure the user-friendliest operation possible. The IAQ probe measures Indoor Air Quality by measuring the CO2 level, air moisture and air temperature. In addition, the lux probe and comfort level probe can be connected to assess draught air. Clear analysis and archiving ensure practical PC documentation. Temperature and humidity measurement is integrated in the thermal probe. The special flow protocol professionally documents duct measurements. It is also possible to connect additional temperature and humidity probes. Readings from up to 3 temperature or humidity probes can be clearly displayed in the measuring instrument; data transmission is by radio, i.e. wireless.
- Instrument memory for 10,000 readings
- PC software for analysis, archiving and documenting data
- IAQ probe, lux probe and comfort level probe
- Vane measurement and thermal probes
- Radio probes for temperature and humidity
- Protection class IP54
|
Storage temperature
|
-30 to +70 °C
|
|
Operating temperature
|
-20 to +50 °C
|
|
Battery type
|
Alkali manganese, mignon, Type AA
|
|
Battery life
|
200 h (typical vane measurement)
|
|
Weight
|
428 g
|
|
Dimensions
|
220 x 74 x 46 mm
|
|
Material/Housing
|
ABS/TPE/Metal
|
|
Probe - Type T (Cu-CuNi)
|
|
Meas. range
|
-200 to +400 °C
|
|
Accuracy
|
±0.3 °C (-60 to +60 °C)
±(0.2 °C +0.3% of mv) (remaining range)
|
|
Resolution
|
0.1 °C
|
|
Probe - NTC
|
|
Meas. range
|
-50 to +150 °C
|
|
Accuracy
|
±0.2 °C(-25 to +74.9 °C)
±0.4 °C (-50 to -25.1 °C)
±0.4 °C (+75 to +99.9 °C)
±0.5% of mv (remaining range)
|
|
Resolution
|
0.1 °C
|
|
Probe - Type K
|
|
Meas. Range
|
-200 to +1370 °C
|
|
Accuracy
|
±0.3 °C (-60 to +60 °C)
±(0.2 °C +0.3% of mv) (remaining range)
|
|
Resolution
|
0.1 °C
|
|
Probe - CO2
|
|
Meas. Range
|
0 to +10000 ppm CO2
|
|
Resolution
|
1 ppm CO2
|
|
Probe - Absolute pressure probe
|
|
Meas. Range
|
0 to +2000 hPa
|
|
Resolution
|
0.1 hPa
|
|
Probe - humid. sensor, cap.
|
|
Meas. Range
|
0 to +100 %RH
|
|
Resolution
|
0.1 %RH
|
|
Probe - Hot Wire
|
|
Meas. Range
|
0 to +20 m/s
|
|
Resolution
|
0.01 m/s
|
|
Probe - Vane
|
|
Meas. Range
|
0 to +60 m/s
|
|
Resolution
|
0.01m/s (60 vane)
0.1 m/s (16 vane)
|
For calibration on this instrument please call us on 01420 544 433