Testo 320 - Flue Gas Analyser

Award Winning Testo 320 Flue Gas Analyser. Find malfunctions, Monitor legal limit values and perform spot checks
Manufacturer: Testo

Products

Picture of Testo 320-1 - Flue Gas Analyser (standard kit)
Testo 320-1 - Flue Gas Analyser (standard kit)
Includes: Fitted 02 and CO Sensors, Hard Travel Case, Rechargeable Battery, USB Cable, 180mm probe & 5 x replacement filters.
Part number: 0563 3220 70
£799.00 (ex VAT)
Picture of Testo 320-1 - Flue Gas Analyser (printer kit)
Testo 320-1 - Flue Gas Analyser (printer kit)
Includes: Fitted 02 and CO Sensors, Testo IRDA Printer, Hard Case, Rechargeable Battery, USB cable, 180mm Probe, 5 x replacement filters.
Part number: 0563 3220 71
£959.00 (ex VAT)
Picture of Testo 320-2 - Flue Gas Analyser (printer kit)
Testo 320-2 - Flue Gas Analyser (printer kit)
Includes: Full contents of the 320-1 printer kit, PLUS: H2 compensated sensor.
Part number: 0563 3220 76
£999.00 (ex VAT)
Picture of Testo 320-2 - Flue Gas Analyser (standard kit)
Testo 320-2 - Flue Gas Analyser (standard kit)
Includes: Full Contents of the 320-1 standard kit, PLUS: H2 compensated sensor.
Part number: 0563 3220 75
£849.00 (ex VAT)

Description

 

Testo 320 - Top Product 2013 Award winner from PHPI Magazine

Product detail

The Testo 320 is a high-quality measuring instrument for efficient flue gas analysis. Its wide measuring range makes it a reliable tool for eliminating malfunctions and emergencies, monitoring legal limit values or for daily routine work, servicing heating systems. Country specific standardised menu procedures, stored in the instrument and the high definition display make operation simple. Excellent visibility allows detailed presentation of the measurement procedures even under the worst conditions and forms the basis for a graphical flue gas analysis – making your work on a heating system considerably easier.

Sensors and Probes

The testo 320 has two measurement sensors for O2 and CO, as well as a temperature sensor integrated into the flue gas probe, for the direct measurement of temperature, O2 and CO. From these data, the instrument calculates all relevant flue gas measurement parameters such as CO2 value, degree of effectively and flue gas loss.

Direct draught or pressure measurements are additionally possible. Using the fine pressure probe, the flue draught or gas pressure values can optionally be measured parallel to the flue gas measurement. Also available: Sensors for CO measurement with H2 compensation and COlow measurement. Using the respective probe, the CO2 content and the CO content in the surroundings can be measured.

Quick and Easy to Use

Thanks to the automatic zeroing or the gas sensor, the instrument is ready to measure shortly after being switched on – only 30 seconds to start. For the measurement parameters O2, CO, temperature and pressure, the testo 320 has been TÜV-tested according to EN 50379, Parts 1-3.

The new flue gas analyser testo 320 solves every measurement task on a heating system. It offers numerous measurement menus, for example for flue gas, draught, differential pressure and ambient CO measurement. The large selection of variable probes makes the testo 320 even more efficient. You have everything you need for complex measurements on heating systems in one instrument. With the testo 320, you comply with all legal guidelines.

High-resolution graphic display - The measurement menus and measurement values are presented in detail and always well legible.

  • Sensor monitoring - Integriated traffic light system which continuously monitors the sensor functionality.
  • Stamp of approval - The flue gas analyzer testo 320 is TÜV-tested according to EN 50379, Parts 1-3
  • Automatic zeroing of sensor - Automatic zeroing of the gas sensor in only 30 seconds after starting, which can be cancelled if not required.
  • Lithium rechargeable battery - Operation with lithium rechargeable battery (1500 mAh) – no need to change battery, up to eight hours running time, charging via USB possible.
  • Attachment - Integrated magnets for fast attachment to burner.
  • Probe filter - Easy exchange of probe filter.
  • Memory - Up to 500 measurement protocols can be stored and called up.

 

Technical Data and Specification

Storage temp. -20 to +50 °C
Oper. temp. -5 to +45 °C
Power supply Rech. batt.: 3.7 V / 2400 mAh
Mains unit: 6 V/1.2 A
Memory 500 readings
Display Colour graphic display with 240 x 320 Pixel
Weight 573 g
Dimensions L 240 x W 85 x H 65 mm
Warranty Instrument/probes/gas sensors:
24 months
Rech. batt.: 12 months

 

  Measuring range Accuracy ±1 Digit Resolution Adjustment time t90
Temperature -40 to +1200 °C Accuracy: ±0,5°C (0 to 100°C)
Accuracy: ±0.5% of m.v. remaining range
0.1 °C -40 to +999,9°C
1 °C; from +1000°C:
-
Draught measurement -9.99 hPa to
+40.00 hPa
± 0.02 hPa or
± 5% of m.v. (at -0,50 to +0,60 hPa)
± 0.03 hPa (0.61 to 3.00 hPa)
± 1.5% of m.v. (at 3.01 to 40.00 hPa))
0.01 hPa
with fine draught option
0.001 hPa
-
Pressure measurement 0 to +300 hPa ±0.5 hPa (0.0 to +500 hPa)
± 1 % of m.v. (at 50.1 to 100.0 hPa)
± 1,5 % of m.v. (at 100,1 to 300,0 hPa)
0.1 hPa with fine pressure
option 0.01
-
O2measurement 0 to 21 vol.% ± 0.2 vol.% 01 vol. % < 20 sec
CO measurement
(without H2 compensation)
0 to 4000 ppm ±3 ppm (0 to 30 ppm)
±10 % of M.V. (31 to 200 ppm)
±20 ppm (201 - 400 ppm)
±5 % of M.V. (401 to 2000 ppm)
±10 % of M.V. (2001 to 4000 ppm)
1 ppm < 60 sec
CO measurement
(with H2 compensation)
0 to 8000 ppm ±3 ppm (0 to 30 ppm)
±10 % of M.V. (31 to 200 ppm)
±20 ppm (201 - 400 ppm)
±5 % of M.V. (401 to 2000 ppm)
±10 % of M.V. (2001 to 8000 ppm)
1 ppm < 40 sec
Efficiency testing
(Eta)
0to120 % - 01 % -
Exhaust gas loss 0 to 99.9 % - 01 % -
CO2 determination
digital calculation from O2
0 to CO2 max ± 0.2 vol.% 01 % -
Option COlow measurement
(H2-compensated)
0 to 500 ppm ±2 ppm (0 to 39 ppm)
±5% of m.v. (40 to 500 ppm)
01 ppm < 40 sec
Ambient CO measurement
(with CO probe)
0 to 500 ppm ±5 ppm (0 to 100 ppm)
±5 % of m.v. (>100 ppm)
1 ppm -
Gas leak measurement
for combustible
gases (with gas
leak detector probe)
0 to 10,000 ppm
CH4 / C3H8
Signal
Optical display (LED)
Audible alarm via buzzer
- < 2 sec
Ambient CO2 measurement
(with ambient CO2
probe)
0 to to 1 vol. %
0 to 10,000 ppm
± 50 ppm or ±2% of m.v. (0 to 5000 ppm)
± 100 ppm or ±3% of m.v. (5001 to 100000
ppm)
- -

 

Service and Calibration

For calibration of this instrument, please call us on 01420 544 433 and quote the below Service and Part Number: